Oxygen profiles and oxygen consumption in the isolated mouse retina

The retina has a large demand for oxygen, but there is only limited information on differences between oxygen utilization (QO2) in the inner and outer retina, and limited data on mouse, which has become a prevalent animal model. This study utilized the isolated mouse retina, which allowed more detai...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Experimental eye research 2023-08, Vol.233, p.109554-109554, Article 109554
Hauptverfasser: Linsenmeier, Robert A., Dmitriev, Andrey V., Dmitriev, Alexander A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The retina has a large demand for oxygen, but there is only limited information on differences between oxygen utilization (QO2) in the inner and outer retina, and limited data on mouse, which has become a prevalent animal model. This study utilized the isolated mouse retina, which allowed more detailed spatial analysis of QO2 than other methods. Oxygen sensitive microelectrodes were used to obtain profiles of oxygen tension across the isolated mouse retina, and mathematical models of retinal oxygen diffusion with four and five layers were fitted to the data to obtain values for QO2 of the outer retina (QOR) and inner retina (QIR). The boundaries between layers were free parameters in these models. The five-layer model resulted in lower error between the model and data, and agreed better with known anatomy. The three layers for the outer retina occupied half of the retina, as in prior work on rat, cat, and monkey, and the inner half of the retina could be divided into two layers, in which the one closer to the vitreous (layer 5) had much lower QO2 than the more distal inner retina (layer 4). QIR in darkness was 3.9 ml O2-100 g−1-min−1, similar to the value for intact cat retina, and did not change during light. QOR in darkness was 2.4 ml O2-100 g−1-min−1, lower than previous values in cat and rat, possibly because of damage to photoreceptors during isolation. There was a tendency for QOR to be lower in light, but it was not significant in this preparation. •Oxygen was recorded with microelectrodes in the isolated retina of C57Bl/6J mice.•Fits of a diffusion model to data revealed five layers with different O2 consumption.•The inner retina had two layers, with O2 consumption much lower near the vitreous.•O2 consumption per gram of mouse retina is similar to that in rat and cat.
ISSN:0014-4835
1096-0007
1096-0007
DOI:10.1016/j.exer.2023.109554