Major complications after ultrasound-guided liver biopsy: An annual audit of a Chinese tertiary-care teaching hospital
As ultrasound-guided percutaneous liver biopsy (PLB) has become a standard and important method in the management of liver disease in our country, a periodical audit of the major complications is needed. To determine the annual incidence of major complications following ultrasound-guided PLB and to...
Gespeichert in:
Veröffentlicht in: | World journal of gastrointestinal surgery 2023-07, Vol.15 (7), p.1388-1396 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | As ultrasound-guided percutaneous liver biopsy (PLB) has become a standard and important method in the management of liver disease in our country, a periodical audit of the major complications is needed.
To determine the annual incidence of major complications following ultrasound-guided PLB and to identify variables that are significantly associated with an increased risk of major complications.
A total of 1857 consecutive cases of PLB were included in our hospital from January 2021 to December 2021. The major complication rate and all-cause 30-d mortality rate were determined. Multivariate analyses were performed by logistic regression to investigate the risk factors associated with major complications and all-cause 30-d mortality following ultrasound-guided PLB.
In this audit of 1857 liver biopsies, 10 cases (0.53%) of major complications occurred following ultrasound-guided PLB. The overall all-cause mortality rate at 30 d after PLB was 0.27% (5 cases). Two cases (0.11%) were attributed to major hemorrhage within 7 d after liver biopsy. Fibrinogen less than 2 g/L [odds ratio (OR): 17.226; 95% confidence interval (CI): 2.647-112.102;
= 0.003], post-biopsy hemoglobin level (OR: 0.963; 95%CI: 0.942-0.985;
= 0.001), obstructive jaundice (OR: 6.698; 95%CI: 1.133-39.596;
= 0.036), application of anticoagulants/antiplatelet medications (OR: 24.078; 95%CI: 1.678-345.495;
= 0.019) and age (OR: 1.096; 95%CI: 1.012-1.187;
= 0.025) were statistically associated with the incidence of major complications after PLB.
In conclusion, the results of this annual audit confirmed that ultrasound-guided PLB can be performed safely, with a major complication rate within the accepted range. Strict patient selection and peri-biopsy laboratory assessment are more important than procedural factors for optimizing the safety outcomes of this procedure. |
---|---|
ISSN: | 1948-9366 1948-9366 |
DOI: | 10.4240/wjgs.v15.i7.1388 |