Continuous positive airway pressure (CPAP) for apnoea of prematurity
Background Apnoea of prematurity (AoP) is defined as a pause in breathing for 20 seconds or longer, or for less than 20 seconds when accompanied by bradycardia and hypoxaemia, in a preterm infant. An association between the severity of apnoea and neurodevelopmental delay has been reported. Continuou...
Gespeichert in:
Veröffentlicht in: | Cochrane database of systematic reviews 2023-07, Vol.2023 (9), p.CD013660 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Apnoea of prematurity (AoP) is defined as a pause in breathing for 20 seconds or longer, or for less than 20 seconds when accompanied by bradycardia and hypoxaemia, in a preterm infant. An association between the severity of apnoea and neurodevelopmental delay has been reported. Continuous positive airway pressure (CPAP) is a form of non‐invasive ventilatory assistance that has been shown to be relatively safe and effective in preventing and treating respiratory distress among preterm infants. It is less clear whether CPAP treatment is safe and effective in the prevention and treatment of AoP.
Objectives
1. To assess the effects of CPAP on AoP in preterm infants (this may be compared to supportive care or mechanical ventilation).
2. To assess the effects of different CPAP delivery systems on AoP in preterm infants.
Search methods
Searches were conducted in September 2022 in the following databases: Cochrane Library, MEDLINE, Embase, and CINAHL. We also searched clinical trial registries and the reference lists of studies selected for inclusion.
Selection criteria
We included all randomised and quasi‐randomised controlled trials (RCTs) in which researchers determined that CPAP was necessary for AoP in preterm infants (born before 37 weeks). Cross‐over studies were also included, provided sufficient data were available for analysis.
Data collection and analysis
We used the standard methods of Cochrane and Cochrane Neonatal, including independent assessment of risk of bias and extraction of data by at least two review authors. Discrepancies were resolved by involvement of a third author. We used the GRADE approach to assess the certainty of evidence for the following outcomes: 1) failed CPAP; 2) apnoea; 3) adverse effects of CPAP.
Main results
We included four single‐centre trials conducted in Malaysia, Spain, Germany, and North America, involving 138 infants with a mean/median gestation of 26 to 28 weeks. Two studies were parallel‐group RCTs and two were cross‐over trials. None of the studies compared CPAP with supportive care. All trials compared one form of CPAP with another. Two compared a variable flow device with ventilator CPAP, one compared two different variable flow devices, and one compared a variable flow device with bubble CPAP. Interventions were administered for periods ranging between six and 48 hours, with pressures between 4 and 6 cm H2O. We assessed all trials as having a high risk of bias for blinding of participants and personn |
---|---|
ISSN: | 1465-1858 1469-493X 1465-1858 1469-493X |
DOI: | 10.1002/14651858.CD013660.pub2 |