Prospects of Endovenous Laser Ablation (EVLA) Standardization-Mid-Term Results of a Four-Zone Dosimetry Guiding Tool for 1940 nm Laser
Heterogeneity regarding dosimetry and reporting of endovenous laser ablation (EVLA) mandates the development of a standardized protocol. This study presents the mid-term results of EVLA with 1940 nm-laser and radial-fibre, supported by a four-zone dosimetry tool. Four anatomical dosimetry zones for...
Gespeichert in:
Veröffentlicht in: | Journal of clinical medicine 2023-06, Vol.12 (13), p.4313 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Heterogeneity regarding dosimetry and reporting of endovenous laser ablation (EVLA) mandates the development of a standardized protocol. This study presents the mid-term results of EVLA with 1940 nm-laser and radial-fibre, supported by a four-zone dosimetry tool.
Four anatomical dosimetry zones for great saphenous veins (GSV) and two for small saphenous veins (SSV) were defined with set power levels. Zone-1G (4 W) extended from the inguinal ligament to the apex of femoral triangle, Zone-2G (4 W) from the apex of femoral triangle to the upper border of patella. Zone-3G (3 W) from the patella to the tibial tuberosity. Zone-4G (2 W) extended from the tibial tuberosity to the ankle. Zone-1S from the sapheno-popliteal junction to the tibial tuberosity. Zone-2S from the tibial tuberosity to the ankle. Power was increased by 1 W for veins >10 mm and decreased by 1 W when fibre sticking was encountered. Pullback-velocity was max. 1 mm/s.
A total of 152 consecutive patients (185 procedures) were recruited. Mean follow-up time was 11.9 months. Mean linear endovenous energy density for GSV was Zone-1G:42 J/cm, Zone-2G:33 J/cm, Zone-3G:27 J/cm, Zone-4G:22 J/cm, Zone-1S:34 J/cm, Zone-2S:27 J/cm. Occlusion rates were 98.9% (1-month) and 93.7% (12-months). Complications at 1 M were low, namely laser-induced paraesthesia (LIP) 2.2% and endovenous heat-induced thrombosis (EHIT) 1.6%. Persistent LIP (12 M) was observed in 0.5%.
The proposed four-zone guiding tool is a step towards standardizing dosimetry and documentation for EVLA with 1940 nm. This strategy shows good mid-term results with minimal complications. Long-term follow-up and application in further centres are necessary to prove its reproducibility. Such a guiding tool could improve the ability to analyse, compare and review different EVLA wavelengths and fibre types. |
---|---|
ISSN: | 2077-0383 2077-0383 |
DOI: | 10.3390/jcm12134313 |