Weight Matching in Infant Heart Transplantation: A National Registry Analysis
Infants account for a significant proportion of pediatric heart transplantation but also suffer from a high waitlist mortality. Donor oversizing by weight-based criteria is common practice in transplantation and is prevalent in this group. We sought to analyze the impact of oversizing on outcomes in...
Gespeichert in:
Veröffentlicht in: | The Annals of thoracic surgery 2023-12, Vol.116 (6), p.1241-1248 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Infants account for a significant proportion of pediatric heart transplantation but also suffer from a high waitlist mortality. Donor oversizing by weight-based criteria is common practice in transplantation and is prevalent in this group. We sought to analyze the impact of oversizing on outcomes in infants.
Infant heart transplantations reported to the United Network for Organ Sharing from January 1994 to September 2019 were retrospectively analyzed. 2384 heart transplantation recipients were divided into quintiles (Q1-Q5) on the basis of donor-to-recipient weight ratio (DRWR). Multivariate Cox regression was used to estimate the effect of DRWR. The primary end point was graft survival at 1 year.
The median DRWR for each quintile was 0.90 (0.37-1.04), 1.17 (1.04-1.29), 1.43 (1.29-1.57), 1.74 (1.58-1.97), and 2.28 (1.97-5.00). Pairwise comparisons showed improved survival for Q3 and Q4 over each of the bottom 2 quintiles and the top quintile. Regression analyses found that Q3 and Q4 were protective against graft failure compared with the bottom 2 quintiles. There was no difference in hazard among the top 3 quintiles. Significant covariates included primary diagnosis, ischemia time, serum bilirubin level, transplantation year, mechanical ventilation at transplantation, and extracorporeal membrane oxygenation at transplantation. Sex, female-to-male transplantation, and mechanical circulatory support at transplantation were not significant in univariate analyses.
Modest oversizing by DRWR (1.29-1.97) is associated with increased survival and lower risk in infant heart transplantation. Additional investigation is needed to establish best practices for size matching in this population.
[Display omitted] |
---|---|
ISSN: | 0003-4975 1552-6259 1552-6259 |
DOI: | 10.1016/j.athoracsur.2022.05.067 |