A ROTEM-guided algorithm aimed to reduce blood product utilization during neonatal and infant cardiac surgery

Neonates and infants undergoing cardiac surgery tend to receive high volumes of blood products. The use of rotational thromboelastometry (ROTEM ) has been shown to reduce the administration of blood products in adults after cardiac surgery. We sought to develop a targeted administration of blood pro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of extra-corporeal technology 2023-06, Vol.55 (2), p.60-69
Hauptverfasser: Naguib, Aymen N, Carrillo, Sergio A, Corridore, Marco, Bigelow, Amee M, Walczak, Ashley, Tram, Nguyen K, Hersey, Diane, Galantowicz, Mark, Tobias, Joseph D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Neonates and infants undergoing cardiac surgery tend to receive high volumes of blood products. The use of rotational thromboelastometry (ROTEM ) has been shown to reduce the administration of blood products in adults after cardiac surgery. We sought to develop a targeted administration of blood products based on ROTEM to reduce blood product utilization during and after neonatal and infant cardiac surgery. We conducted a retrospective review of data from a single center for neonates and infants undergoing congenital cardiac surgery using cardiopulmonary bypass (CPB) from September 2018-April 2019 (control group). Then, using a ROTEM algorithm, we collected data prospectively between April-November 2021 (ROTEM group). Data collected included age, weight, gender, procedure, STAT score, CPB time, aortic cross-clamp time, volume, and type of blood products administered in the operating room and cardiothoracic intensive care unit (CTICU). In addition, ROTEM data, coagulation profile in CTICU, chest tube output at 6 and 24 hours, use of factors concentrate, and thromboembolic complications were recorded. The final cohort of patients included 28 patients in the control group and 40 patients in the ROTEM group. The cohort included neonates and infants undergoing the following procedures: arterial switch, aortic arch augmentation, Norwood procedure, and comprehensive stage II procedure. There were no differences in the demographics or procedure complexity between the two groups. Patients in the ROTEM group received fewer platelets (36 ± 12 vs. 49 ± 27 mL/kg, p 0.028) and cryoprecipitate (8 ± 3 vs. 15 ± 10 mL/kg, p 0.001) intraoperatively when compared to the control group. The utilization of ROTEM may have contributed to a significant reduction in some blood product administration during cardiac surgery for infants and neonates. ROTEM data may play a role in reducing blood product administration in neonatal and infant cardiac surgery.
ISSN:0022-1058
2969-8960
DOI:10.1051/ject/2023017