A New Criterion for Shear Wave Elastometric Assessment Using Modulus of Stiffness Difference between Object and Environment

Ultrasound shear wave elastography is a modern method that is based on measuring the shear wave velocity making it possible to determine stiffness of soft biological tissues at an arbitrary point (point elastography) or to construct a two-dimensional color image with a subsequent point measurement o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sovremennye tekhnologii v medit͡s︡ine 2022-01, Vol.14 (5), p.5-13
Hauptverfasser: Demin, I Yu, Rykhtik, P I, Spivak, А E, Safonov, D V
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Ultrasound shear wave elastography is a modern method that is based on measuring the shear wave velocity making it possible to determine stiffness of soft biological tissues at an arbitrary point (point elastography) or to construct a two-dimensional color image with a subsequent point measurement of stiffness (two-dimensional elastography) and therefore to compare the stiffness of an object with a medium or objects with each other. is to develop a new criterion for the comparative assessment of objects with different stiffness during shear wave elastometry: modulus of stiffness difference between object and environment. Using the original technology of building two-dimensional color elastogram, point and two-dimensional shear wave elastography were performed using linear sensors on commercial ultrasound scanners: Aixplorer (SuperSonic Imagine, France), Acuson S2000 (Siemens, Germany), and Verasonics acoustic system (Verasonics Inc., USA) with an open architecture to determine the stiffness values of focal inclusions and compare them with each other with the help of a new comparative elastomeric assessment criterion: modulus of stiffness difference between object and environment. First, the accuracy of the scanners under test was compared on a calibrated Elasticity QA Phantom, model 049 (Computerized Imaging Reference Systems Company, USA) with a known stiffness of various inclusions and thereafter on an uncalibrated BP1901 phantom (Blue Phantom, USA) with unknown stiffness of inclusions. The obtained values were compared to determine the influence of subjective factors on the measurement results. To assess the stiffness of the foci and compare the values with each other taking into account the rigidity of the environment, it is proposed to use a new criterion for the comparative assessment - the modulus of stiffness difference between focus and environment, which quantitatively characterizes the difference between these values. According to this criterion, all three ultrasound scanners have been established to show high and comparable accuracy in determining the stiffness of inclusions within the homogeneous medium in the experiments on phantoms. Two-dimensional shear wave elastography has revealed the effect of the control volume size and the correctness of the color scale setting, especially in the heterogeneous objects, on the results of elastometry. Methodological techniques to reduce the influence of subjective factors have also been proposed. The st
ISSN:2076-4243
2309-995X
DOI:10.17691/stm2022.14.5.01