Implementation of automated personalised breast radiotherapy planning techniques with scripting in Raystation

Implement scripted automatic breast planning (AP) for breast techniques within Raystation. Manual plans (MPs) were re-planned and compared with AP plans for whole breast (WB), partial breast (PB), hybrid volumetric modulated arc therapy simultaneous integrated boost (VMAT SIB) and VMAT nodal plans....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:British journal of radiology 2023-03, Vol.96 (1144), p.20220707-20220707
Hauptverfasser: Gleeson, Ian, Bolger, Niall, Chun, Harmony, Hutchinson, Katie, Klodowska, Magdalena, Mehrer, Jennifer, Toomey, Marian
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Implement scripted automatic breast planning (AP) for breast techniques within Raystation. Manual plans (MPs) were re-planned and compared with AP plans for whole breast (WB), partial breast (PB), hybrid volumetric modulated arc therapy simultaneous integrated boost (VMAT SIB) and VMAT nodal plans. WB AP plans took 7 min comparing well to MP. One WB AP failed a mandatory dose constraint. Small statistically significant differences showed improved coverage for AP at expense of slightly hotter plans, however absolute differences were small (mean differences < 1% or D
ISSN:0007-1285
1748-880X
DOI:10.1259/bjr.20220707