Implementation of automated personalised breast radiotherapy planning techniques with scripting in Raystation
Implement scripted automatic breast planning (AP) for breast techniques within Raystation. Manual plans (MPs) were re-planned and compared with AP plans for whole breast (WB), partial breast (PB), hybrid volumetric modulated arc therapy simultaneous integrated boost (VMAT SIB) and VMAT nodal plans....
Gespeichert in:
Veröffentlicht in: | British journal of radiology 2023-03, Vol.96 (1144), p.20220707-20220707 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Implement scripted automatic breast planning (AP) for breast techniques within Raystation.
Manual plans (MPs) were re-planned and compared with AP plans for whole breast (WB), partial breast (PB), hybrid volumetric modulated arc therapy simultaneous integrated boost (VMAT SIB) and VMAT nodal plans.
WB AP plans took 7 min comparing well to MP. One WB AP failed a mandatory dose constraint. Small statistically significant differences showed improved coverage for AP at expense of slightly hotter plans, however absolute differences were small (mean differences < 1% or D |
---|---|
ISSN: | 0007-1285 1748-880X |
DOI: | 10.1259/bjr.20220707 |