Performance of immunochromatographic and immunoenzymatic techniques in the diagnosis of toxoplasmosis in pregnant women in Cameroon: need for harmonization
in order to contribute to the improvement of the management of toxoplasmosis in pregnant women in Cameroon, performance of two techniques commonly used in the diagnosis of toxoplasmosis was evaluated. a total of 541 pregnant women were recruited from seven hospitals in two Regions of Cameroon, of wh...
Gespeichert in:
Veröffentlicht in: | The Pan African medical journal 2022, Vol.43, p.195-195 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | in order to contribute to the improvement of the management of toxoplasmosis in pregnant women in Cameroon, performance of two techniques commonly used in the diagnosis of toxoplasmosis was evaluated.
a total of 541 pregnant women were recruited from seven hospitals in two Regions of Cameroon, of which 63% (341: Batch1) were from health facilities (HF) using a immunochromatographic technique (ICT) as a screening test for toxoplasmosis, and 37% (200: Batch2) from those using an immunoenzymatic technique (IEZ). On each sample, Ig (Immunoglobulin) G (IgG) and IgM were tested by three techniques: a Rapid Diagnostic Test (RDT), an Enzyme Linked Immuno Sorbent Assay (ELISA) and a Vidas Enzyme-linked fluorescent assay taken as reference (VIDAS/ELFA). The results from the health facilities were recorded.
for the IgG assay, our two laboratory methods were sensitive (96.0% and 97.5%) and specific (64.2% and 59.7%). Their concordance rates with the VIDAS/ELFA reference were above 60% (P |
---|---|
ISSN: | 1937-8688 1937-8688 |
DOI: | 10.11604/pamj.2022.43.195.36996 |