Proposal and multicentric validation of a laparoscopic Roux-en-Y gastric bypass surgery ontology
Background Phase and step annotation in surgical videos is a prerequisite for surgical scene understanding and for downstream tasks like intraoperative feedback or assistance. However, most ontologies are applied on small monocentric datasets and lack external validation. To overcome these limitatio...
Gespeichert in:
Veröffentlicht in: | Surgical endoscopy 2023-03, Vol.37 (3), p.2070-2077 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Phase and step annotation in surgical videos is a prerequisite for surgical scene understanding and for downstream tasks like intraoperative feedback or assistance. However, most ontologies are applied on small monocentric datasets and lack external validation. To overcome these limitations an ontology for phases and steps of laparoscopic Roux-en-Y gastric bypass (LRYGB) is proposed and validated on a multicentric dataset in terms of inter- and intra-rater reliability (inter-/intra-RR).
Methods
The proposed LRYGB ontology consists of 12 phase and 46 step definitions that are hierarchically structured. Two board certified surgeons (raters) with > 10 years of clinical experience applied the proposed ontology on two datasets: (1) StraBypass40 consists of 40 LRYGB videos from Nouvel Hôpital Civil, Strasbourg, France and (2) BernBypass70 consists of 70 LRYGB videos from Inselspital, Bern University Hospital, Bern, Switzerland.
To assess inter-RR the two raters’ annotations of ten randomly chosen videos from StraBypass40 and BernBypass70 each, were compared. To assess intra-RR ten randomly chosen videos were annotated twice by the same rater and annotations were compared.
Inter-RR was calculated using Cohen’s kappa. Additionally, for inter- and intra-RR accuracy, precision, recall, F1-score, and application dependent metrics were applied.
Results
The mean ± SD video duration was 108 ± 33 min and 75 ± 21 min in StraBypass40 and BernBypass70, respectively. The proposed ontology shows an inter-RR of 96.8 ± 2.7% for phases and 85.4 ± 6.0% for steps on StraBypass40 and 94.9 ± 5.8% for phases and 76.1 ± 13.9% for steps on BernBypass70. The overall Cohen’s kappa of inter-RR was 95.9 ± 4.3% for phases and 80.8 ± 10.0% for steps. Intra-RR showed an accuracy of 98.4 ± 1.1% for phases and 88.1 ± 8.1% for steps.
Conclusion
The proposed ontology shows an excellent inter- and intra-RR and should therefore be implemented routinely in phase and step annotation of LRYGB. |
---|---|
ISSN: | 0930-2794 1432-2218 |
DOI: | 10.1007/s00464-022-09745-2 |