Relations between scatter factor, quality index and attenuation for x-ray beams

The relations between the attenuation factor, the normalized phantom scatter factor and the quality index are examined using a semiempirical formula for the dose on the central axis of an x-ray beam in water. The study is restricted to depths and field sizes sufficient for electron equilibrium. The...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physics in medicine & biology 1998-05, Vol.43 (5), p.1325-1330
Hauptverfasser: Bjärngard, Bengt E, Vadash, Paul
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The relations between the attenuation factor, the normalized phantom scatter factor and the quality index are examined using a semiempirical formula for the dose on the central axis of an x-ray beam in water. The study is restricted to depths and field sizes sufficient for electron equilibrium. The results are compared with data in the recent literature. It is concluded that for x-ray beams in the energy range 4-25 MV the normalized scatter factors can be calculated from the dose-weighted average linear attenuation coefficient in water, determined from transmission measurements in a narrow-beam geometry or from the quality index.
ISSN:0031-9155
1361-6560
DOI:10.1088/0031-9155/43/5/020