Fixation of femoral neck fracture: A randomized 2-year follow-up study of hook pins and sliding screw plate in 222 patients
We compared fixation with hook pins or sliding screw plate in a prospective randomized study of 222 patients with a cervical hip fracture. Radiographic evidence of early redisplacement, nonunion, or late segmental collapse was found in 43 of 122 patients operated on with two hook pins and in 40 of 1...
Gespeichert in:
Veröffentlicht in: | Acta orthopaedica 1995, Vol.66 (6), p.507-510 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We compared fixation with hook pins or sliding screw plate in a prospective randomized study of 222 patients with a cervical hip fracture. Radiographic evidence of early redisplacement, nonunion, or late segmental collapse was found in 43 of 122 patients operated on with two hook pins and in 40 of 100 patients operated on with the sliding screw plate. According to the actuarial method, the failure rate after 2 years was 38% with hook pins and 46% with screw plates, which not is a significant difference.
Due to early redisplacement, reoperation with an endoprosthesis was performed within 0.5 (2) years in 11 (22) patients in the hook-pin group and in 4 (17) patients in the sliding-screw plate group. |
---|---|