Comparative pressure measurements in the oesophagus by means of in situ tip-transducers and external transducer systems

Basal gastro-oesophageal sphincter pressures and peak peristaltic pressure amplitudes in the oesophageal body 5 and 15 cm proximal to the gastro-oesophageal sphincter were measured with three different set ups in six healthy volunteers. The in situ tip-transducer measurements were compared to two di...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Scandinavian journal of clinical and laboratory investigation 1978, Vol.38 (4), p.375-381
Hauptverfasser: Wallin, Lene, Boesby, Steen, Madsen, Tommy
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Basal gastro-oesophageal sphincter pressures and peak peristaltic pressure amplitudes in the oesophageal body 5 and 15 cm proximal to the gastro-oesophageal sphincter were measured with three different set ups in six healthy volunteers. The in situ tip-transducer measurements were compared to two different external pressure transducers in a perfused catheter system and to an external pressure transducer in a non-perfused catheter system. The in situ tip-transducer recorded higher sphincter pressures and peristaltic amplitudes than those recorded by the perfused and non-perfused systems (P
ISSN:0036-5513
1502-7686
DOI:10.3109/00365517809108437