Numerical analysis of the mechanical behavior of ceramic dental implants based on Ce-TZP/Al 2 O 3 composite

This study aimed to identify the potential use of the ceramic composite ZrO (CeO )-Al O as a dental implant due to its intrinsic geometry and different masticatory loads based on finite element simulations. Ceramic samples were sintered at 1500 °C-2h, and characterized: The mechanical properties of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the mechanical behavior of biomedical materials 2024-02, Vol.150, p.106335
Hauptverfasser: da Costa Ward, Pedro Araújo, Ward, Fernando, Alves, Manuel Fellipe Rodrigues Pais, Moreira da Silva, Cosme Roberto, Moreira, Luciano Pessanha, Santos, Claudinei Dos
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study aimed to identify the potential use of the ceramic composite ZrO (CeO )-Al O as a dental implant due to its intrinsic geometry and different masticatory loads based on finite element simulations. Ceramic samples were sintered at 1500 °C-2h, and characterized: The mechanical properties of the ceramic composite (hardness, fracture toughness, flexural strength, Young's Modulus, and Poisson ratio) were determined, in addition to the relative density and its structural characteristics. Commercial dental implant designs (incisal and third-molar) on CAD models were used in this study as an initial implant geometry applied in a typical simulated mandible anatomy. Finite element models were generated for implant geometries using CAD and CAE techniques. Loading cases were considered based on different intensities (100-500 N) and orientation angles to the implant axis (0° and 45°) to reproduce human masticatory conditions. For comparison purposes, the numerical predictions were compared with finite element simulations of gold-standard titanium implants. Ce-TZP/Al O sintered ceramics showed flexural strength of 952.6 ± 88 MPa, hardness and fracture toughness of 1427 ± 46 HV and 11.3 ± 0.4 MPa m , respectively, beside Young's modulus of 228.3 ± 65 GPa and Poisson ratio of 0.28. For both Ce-TZP/Al O dental implant geometries, the implant prototypes showed adequate mechanical behavior regardless of the masticatory load value or the orientation angle applied in the simulations: All finite element predictions are lower than the values established by Mohr Coulomb's failure criterion, allowing the feasibility, preliminarily, of the proposed ceramics for dental implant applications without fracture risk.
ISSN:1878-0180