Transdermal Blood Sampling for C-Peptide Is a Minimally Invasive, Reliable Alternative to Venous Sampling in Children and Adults With Type 1 Diabetes
C-peptide and islet autoantibodies are key type 1 diabetes biomarkers, typically requiring venous sampling, which limits their utility. We assessed transdermal capillary blood (TCB) collection as a practical alternative. Ninety-one individuals (71 with type 1 diabetes, 20 controls; individuals with...
Gespeichert in:
Veröffentlicht in: | Diabetes care 2023-12 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | C-peptide and islet autoantibodies are key type 1 diabetes biomarkers, typically requiring venous sampling, which limits their utility. We assessed transdermal capillary blood (TCB) collection as a practical alternative.
Ninety-one individuals (71 with type 1 diabetes, 20 controls; individuals with type 1 diabetes: aged median 14.8 years [interquartile range (IQR) 9.1-17.1], diabetes duration 4.0 years [1.5-7.7]; controls: 42.2 years [38.0-52.1]) underwent contemporaneous venous and TCB sampling for measurement of plasma C-peptide. Participants with type 1 diabetes also provided venous serum and plasma, and TCB plasma for measurement of autoantibodies to glutamate decarboxylase, islet antigen-2, and zinc transporter 8. The ability of TCB plasma to detect significant endogenous insulin secretion (venous C-peptide ≥200 pmol/L) was compared along with agreement in levels, using Bland-Altman. Venous serum was compared with venous and TCB plasma for detection of autoantibodies, using established thresholds. Acceptability was assessed by age-appropriate questionnaire.
Transdermal sampling took a mean of 2.35 min (SD 1.49). Median sample volume was 50 µL (IQR 40-50) with 3 of 91 (3.3%) failures, and 13 of 88 (14.7%) |
---|---|