A User-Friendly System for Mailed Dosimetric Audits of 192 Ir or 60 Co HDR Brachytherapy Sources

The main goal of this work is to design and characterize a user-friendly methodology to perform mailed dosimetric audits in high dose rate (HDR) brachytherapy for systems using either Iridium-192 ( Ir) or Cobalt-60 ( Co) sources. A solid phantom was designed and manufactured with four catheters and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cancers 2023-04, Vol.15 (9)
Hauptverfasser: Oliver-Cañamás, Laura, Vijande, Javier, Candela-Juan, Cristian, Gimeno-Olmos, Jose, Pujades-Claumarchirant, Mª Carmen, Rovira-Escutia, Juan J, Ballester, Facundo, Perez-Calatayud, Jose
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The main goal of this work is to design and characterize a user-friendly methodology to perform mailed dosimetric audits in high dose rate (HDR) brachytherapy for systems using either Iridium-192 ( Ir) or Cobalt-60 ( Co) sources. A solid phantom was designed and manufactured with four catheters and a central slot to place one dosimeter. Irradiations with an Elekta MicroSelectron V2 for Ir, and with a BEBIG Multisource for Co were performed for its characterization. For the dose measurements, nanoDots, a type of optically stimulated luminescent dosimeters (OSLDs), were characterized. Monte Carlo (MC) simulations were performed to evaluate the scatter conditions of the irradiation set-up and to study differences in the photon spectra of different Ir sources (Microselectron V2, Flexisource, BEBIG Ir2.A85-2 and Varisource VS2000) reaching the dosimeter in the irradiation set-up. MC simulations indicate that the surface material on which the phantom is supported during the irradiations does not affect the absorbed dose in the nanoDot. Generally, differences below 5% were found in the photon spectra reaching the detector when comparing the Microselectron V2, the Flexisource and the BEBIG models. However, differences up to 20% are observed between the V2 and the Varisource VS2000 models. The calibration coefficients and the uncertainty in the dose measurement were evaluated. The system described here is able to perform dosimetric audits in HDR brachytherapy for systems using either Ir or Co sources. No significant differences are observed between the photon spectra reaching the detector for the MicroSelectron V2, the Flexisource and the BEBIG Ir sources. For the Varisource VS2000, a higher uncertainty is considered in the dose measurement to allow for the nanoDot response.
ISSN:2072-6694
2072-6694
DOI:10.3390/cancers15092484