Dose perturbation effects by metal hip prosthesis in gynaecological 192 Ir HDR brachytherapy

The present study was conducted to elucidate the effects of hip prostheses in Ir HDR brachytherapy and determine dose uncertainties introduced by the treatment planning. A gynaecological phantom irradiated using Nucletron Ir microSelectron HDR source was modeled using MCNP5 code. Three hip materials...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied radiation and isotopes 2023-06, Vol.196, p.110751
Hauptverfasser: Ab Shukor, N S, Abdullah, R, Abdul Aziz, M Z, Samson, D O, Musarudin, M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The present study was conducted to elucidate the effects of hip prostheses in Ir HDR brachytherapy and determine dose uncertainties introduced by the treatment planning. A gynaecological phantom irradiated using Nucletron Ir microSelectron HDR source was modeled using MCNP5 code. Three hip materials considered in this study were water, bone, and metal prosthesis. According to the obtained results, a dose perturbation was observed within the medium with a higher atomic number, which reduced the dose to the nearby region.
ISSN:1872-9800