Ultrasensitive immunosensor for monitoring of CA 19-9 pancreatic cancer marker using electrolyte-gated TiS 3 nanoribbons field-effect transistor

Measuring CA 19-9 antigen level is critical for early diagnosis of pancreatic cancer, monitoring the treatment process, and predicting disease recurrence. The purpose of this research is to assess the application of novel few-layered TiS nanoribbons material as a channel material in electrolyte-gate...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2023-05, Vol.257, p.124336
Hauptverfasser: Rahmani, Hedyeh, Mansouri Majd, Samira, Salimi, Abdollah, Ghasemi, Foad
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Measuring CA 19-9 antigen level is critical for early diagnosis of pancreatic cancer, monitoring the treatment process, and predicting disease recurrence. The purpose of this research is to assess the application of novel few-layered TiS nanoribbons material as a channel material in electrolyte-gated field-effect transistor immunosensor for rapid detection of CA 19-9 antigen as a cancer marker. Accordingly, TiS nanoribbons were produced through liquid-phase exfoliation of as-synthesized TiS whiskers in N, N-dimethylformamide. Then, dispersed TiS nanoribbons were drop cast onto the FET surface to form an active channel material between source and drain electrodes. Subsequently, the channel surface was modified by utilizing 1-naphthylamine (NA) and glutaraldehyde (GA) to strengthen the binding of monoclonal antibody 19-9 to TiS nanoribbons. Spectroscopic and microscopic methods were utilized for comprehensive characterizations. Electrical characterization of electrolyte-gated TiS nanoribbons field-effect transistor represented a depletion-mode n-type behavior with field-effect mobility of 0.059 cm /Vs, current on/off ratio of 10.88 and subthreshold swing (SS) of 450.9 mV/decade. With increasing in CA 19-9 antigen concentration from 1.0 × 10 U/mL to 1.0 × 10 U/mL, a decrease in the drain current occurred with high sensitivity of 0.04 μA/decade and a detection limit of 1.3 × 10 U/mL. Additionally, the proposed TiS nanoribbons FET immunosensor exhibited outstanding selectivity, and its good performance was compared with an enzyme-linked immunosorbent assay (ELISA) for spiked real human serum samples. The good and satisfactory obtained results of the proposed immunosensor suggest that the developed platform can be a superb candidate for cancer diagnosis and therapeutic monitoring.
ISSN:1873-3573