Photoelectrochemical immunosensor for the sensitive detection of neuron-specific enolase based on the effect of Z-scheme WO 3 /NiCo 2 O 4 nanoarrays p-n heterojunction

In this study, a signal-on type PEC immunosensor was constructed to detect neuron-specific enolase (NSE) via Z-scheme WO /NiCo O p-n heterojunction with cactus-like structure used as photoactive materials and Mn Cd S⊃Au NPs (MCS⊃Au NPs) as signal labels. Firstly, Z-scheme WO /NiCo O heterojunction c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biosensors & bioelectronics 2022-06, Vol.213, p.114452
Hauptverfasser: Zhang, Yingying, Wu, Tingting, Liu, Deling, Xu, Rui, Ma, Hongmin, Wei, Qin, Zhang, Yong
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, a signal-on type PEC immunosensor was constructed to detect neuron-specific enolase (NSE) via Z-scheme WO /NiCo O p-n heterojunction with cactus-like structure used as photoactive materials and Mn Cd S⊃Au NPs (MCS⊃Au NPs) as signal labels. Firstly, Z-scheme WO /NiCo O heterojunction could accelerate the separation efficiency of carriers and well-matched photoactive materials may promote charge migration, which resulted in WO /NiCo O generating strong and stable current. In addition, Z-scheme WO /NiCo O heterojunction directly grown on the surface of FTO via hydrothermal method facilitated the preparation of PEC immunosensor with outstanding stability. Secondly, an efficient signal amplification strategy was proposed by Mn Cd S⊃Au NPs incubating with signal antibody (Ab ). On the one hand, the well-matched energy levels of Mn Cd S with WO /NiCo O boosted the photo-generated electrons transferred to the electrode; on the other hand, the LSPR effect of Au may convert thermion to photocurrent to achieve signal amplification. Based on the above strategies, a PEC immunosensor with outstanding reproducibility and stability was obtained for sensitive detection of NSE. Under the optimum experimental conditions, current response range of the constructed signal amplification PEC sensor to NSE was 0.1 pg/mL ∼50 ng/mL and the detection limit was 0.07 pg/mL (S/N = 3). After the application tests in the detection of actual samples, the feasibility of the prepared PEC immunosensor with excellent selectivity, high sensitivity and satisfactory reproducibility was verified and the satisfactory results were obtained.
ISSN:1873-4235
DOI:10.1016/j.bios.2022.114452