A reusable, reagent-less free chlorine sensor using gold thin film electrode

Free chlorine is widely used as a disinfectant in the water industry. Accurate monitoring of the residual free chlorine concentration in water cycles is critical to maintain public health safety. Here, we report on a thin gold film-based reusable and reagent-less free chlorine sensor. A gold thin fi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analyst (London) 2021-04, Vol.146 (8), p.2626-2631
Hauptverfasser: Alam, Arif Ul, Clyne, Dennis, Lush, Will, Deen, M. Jamal
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Free chlorine is widely used as a disinfectant in the water industry. Accurate monitoring of the residual free chlorine concentration in water cycles is critical to maintain public health safety. Here, we report on a thin gold film-based reusable and reagent-less free chlorine sensor. A gold thin film of 300 nm thickness was deposited on a polyimide tape, which was placed on a glass substrate and a simple Styrofoam adhesive tape was used to cover the film and expose 0.36 cm2 circular area as the sensing surface. The sensor showed a high sensitivity of 0.327 μA ppm −1 , with a linear range of 0 to 6 ppm, and an accuracy of
ISSN:0003-2654
1364-5528
DOI:10.1039/d1an00038a