COSMIC RADIATION EXPOSURE CALCULATIONS FOR INTERNATIONAL AND DOMESTIC FLIGHTS DEPARTS FROM ISTANBUL AND ANKARA
Abstract In this study, cosmic radiation doses were calculated for domestic and international flights departing from Istanbul and furthermore for domestic flights departing from Ankara using a software program called CARI-7A and also a mathematical method approach. Main parameters for calculating co...
Gespeichert in:
Veröffentlicht in: | Radiation protection dosimetry 2020-12, Vol.192 (1), p.61-68 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
In this study, cosmic radiation doses were calculated for domestic and international flights departing from Istanbul and furthermore for domestic flights departing from Ankara using a software program called CARI-7A and also a mathematical method approach. Main parameters for calculating cosmic radiation are vertical cut-off rigidity, flight duration, latitude–longitude and altitude of the flight. Our calculation results agree with the measurements for domestic and international flights departing from Istanbul and Ankara. |
---|---|
ISSN: | 0144-8420 1742-3406 |
DOI: | 10.1093/rpd/ncaa182 |