An open source heterogeneous 3D printed mouse phantom utilising a novel bone representative thermoplastic

The lack of rigorous quality standards in pre-clinical radiation dosimetry has renewed interest in the development of anthropomorphic phantoms. Using 3D printing customisable phantoms can be created to assess all parts of pre-clinical radiation research: planning, image guidance and treatment delive...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physics in medicine & biology 2020-05, Vol.65 (10), p.10NT02-10NT02
Hauptverfasser: Price, Gareth, Biglin, Emma R, Collins, Sean, Aitkinhead, Adam, Subiel, Anna, Chadwick, Amy L, Cullen, David, M, Kirkby, Karen J, Schettino, Giuseppe, Tipping, Jill, Robinson, Andrew
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The lack of rigorous quality standards in pre-clinical radiation dosimetry has renewed interest in the development of anthropomorphic phantoms. Using 3D printing customisable phantoms can be created to assess all parts of pre-clinical radiation research: planning, image guidance and treatment delivery. We present the full methodology, including material development and printing designs, for the production of a high spatial resolution, anatomically realistic heterogeneous small animal phantom. A methodology for creating and validating tissue equivalent materials is presented. The technique is demonstrated through the development of a bone-equivalent material. This material is used together with a soft-tissue mimicking ABS plastic filament to reproduce the corresponding structure geometries captured from a CT scan of a nude mouse. Air gaps are used to represent the lungs. Phantom validation was performed through comparison of the geometry and x-ray attenuation of CT images of the phantom and animal images. A 6.6% difference in the attenuation of the bone-equivalent material compared to the reference standard in softer beams (0.5 mm Cu HVL) rapidly decreases as the beam is hardened. CT imaging shows accurate (sub-millimetre) reproduction of the skeleton (Distance-To-Agreement 0.5 mm ± 0.4 mm) and body surface (0.7 mm ± 0.5 mm). Histograms of the voxel intensity profile of the phantom demonstrate suitable similarity to those of both the original mouse image and that of a different animal. We present an approach for the efficient production of an anthropomorphic phantom suitable for the quality assurance of pre-clinical radiotherapy. Our design and full methodology are provided as open source to encourage the pre-clinical radiobiology community to adopt a common QA standard. AbbreviationsABS - acrylonitrile butadiene styrene, CBCT - cone beam computed tomography, FDM - fused deposition modelling, HVL - half value layer, HU - Hounsfield units, ICRU - International Commission on Radiation Units and Measurements, NIST - National Institute of Standards and Technology, NPL - National Physical Laboratory, QA - quality assurance, ROI - region of interest, SARRP - small animal radiation research platform, STL - stereolithography.
ISSN:0031-9155
1361-6560
DOI:10.1088/1361-6560/ab8078