An Electrochemical Sensor of Poly(EDOT-pyridine-EDOT)/Graphitic Carbon Nitride Composite for Simultaneous Detection of Cd 2+ and Pb 2
In this study, poly(2,5-bis(3,4-ethylenedioxythienyl)pyridine)/graphitic carbon nitride composites (poly(BPE)/g-C₃N₄) were prepared by an in situ chemical polymerization method. Composites were characterized by using Fourier transform infrared spectroscopy (FT-IR), ultraviolet⁻visible absorption spe...
Gespeichert in:
Veröffentlicht in: | Materials 2018-04, Vol.11 (5) |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this study, poly(2,5-bis(3,4-ethylenedioxythienyl)pyridine)/graphitic carbon nitride composites (poly(BPE)/g-C₃N₄) were prepared by an in situ chemical polymerization method. Composites were characterized by using Fourier transform infrared spectroscopy (FT-IR), ultraviolet⁻visible absorption spectra (UV⁻vis), X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDS), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). Furthermore, electrochemical sensors were applied for the electrochemical determination of Cd
and Pb
using the differential pulse voltammetry (DPV) method. The results indicated that 10 wt % poly(BPE)/g-C₃N₄ composite-modified electrode exhibited linear detection ranging from 0.12 to 7.2 μM and 0.08 to 7.2 μM for Cd
and Pb
, with detection limits (S/N = 3) of 0.018 μM and 0.00324 μM. Interference analysis suggested that the 10 wt % poly(BPE)/g-C₃N₄-modified electrode can be applied for the detection of the Cd
and Pb
in real samples. |
---|---|
ISSN: | 1996-1944 1996-1944 |
DOI: | 10.3390/ma11050702 |