Diagnostic use of neuro-spect quantified with 99m Tc-ECD a model based on normal data
The purpose of the present study was to prospectively quantify the normal limits of brain perfusion using specific software in a group of asymptomatic young volunteers submitted to single-photon emission tomography (SPECT) with Tc-ethyl cysteinate dimer ( Tc-ECD). We used 15 MBq/kg of intravenous Tc...
Gespeichert in:
Veröffentlicht in: | Dementia & neuropsychologia 2013-10, Vol.7 (4), p.416 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The purpose of the present study was to prospectively quantify the normal limits of brain perfusion using specific software in a group of asymptomatic young volunteers submitted to single-photon emission tomography (SPECT) with
Tc-ethyl cysteinate dimer (
Tc-ECD).
We used 15 MBq/kg of intravenous
Tc-ECD in 30 healthy volunteers submitted to brief neuropsychological tests and a clinical questionnaire. These data were normalized relative to the cerebellum (Group 1) and to the brain cortex (Group 2). Statistical analysis was performed with Student's t-test. The average radioactivity was 6.5 million counts/study.
The normalized (Group I) revealed an average value of 78.03%, with standard deviation (SD) of 4.07. Two volunteers in this group had slightly greater than two standard deviations from the mean. When we used (Group II), the average value was 71.01%, with a SD of 4.66. We observed a difference between groups of 9% (P |
---|---|