Specific heat capacity of freshly excised prostate specimens

The specific heat capacity of tissue is a critical parameter for thermal therapies that act over a long period of time. It is also critical for thermoacoustic signal generation. We present ex vivo measurements of specific heat capacity performed by a dual-pin probe with tight temperature control of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physiological measurement 2011-11, Vol.32 (11), p.N55-N64
Hauptverfasser: Patch, S K, Rao, N, Kelly, H, Jacobsohn, K, See, W A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The specific heat capacity of tissue is a critical parameter for thermal therapies that act over a long period of time. It is also critical for thermoacoustic signal generation. We present ex vivo measurements of specific heat capacity performed by a dual-pin probe with tight temperature control of the specimen. One 30 mm × 1.28 mm probe heats steadily for 30 s, while another measurement probe measures temperatures 6 mm away from the center of the heater probe. Specific heat values ranging from 2.9 to 4 J cm(-3) °C(-1) were measured on 20 lobes from ten fresh prostate specimens with varying degrees of cancerous involvement as confirmed by histology.
ISSN:0967-3334
1361-6579
DOI:10.1088/0967-3334/32/11/N02