Novel monoclonal antibodies to ESAT-6 and CFP-10 antigens for ELISA-based diagnosis of pleural tuberculosis

OBJECTIVE: To elucidate the potential of monoclonal antibodies (mAbs) of culture filtrate protein 10 (CFP-10) and early secretory antigenic target 6 (ESAT-6) in tuberculosis (TB) diagnosis.DESIGN: We generated and characterised monoclonal and polyclonal antibodies against Mycobacterium tuberculosis-...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The international journal of tuberculosis and lung disease 2011-06, Vol.15 (6), p.804-810
Hauptverfasser: FENG, T.-T, SHOU, C.-M, YAO, H.-P, SHEN, L, QIAN, Y, WU, Z.-G, FAN, J, ZHANG, Y.-Z, TANG, Y.-W, WU, N.-P, LU, H.-Z
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:OBJECTIVE: To elucidate the potential of monoclonal antibodies (mAbs) of culture filtrate protein 10 (CFP-10) and early secretory antigenic target 6 (ESAT-6) in tuberculosis (TB) diagnosis.DESIGN: We generated and characterised monoclonal and polyclonal antibodies against Mycobacterium tuberculosis-specific antigens ESAT-6 and CFP-10 by immunising BALB/c mice with an ESAT-6/CFP-10 fusion protein. Stable hybridoma cell lines were established and mAbs were specifically identified by immunoblotting and immunoprecipitation. The mouse mAbs were used to coat plates, and biotin-labelled polyclonal antibodies were used to detect the antigens. One hundred and seventy-three samples of sputum culture supernatants and pleural effusion aspirates have been tested.RESULTS: The ESAT-6 enzyme-linked immunosorbent assay (ELISA) detected the culture supernatants and pleural effusion specimens that were positive for M. tuberculosis, but failed to identify M. tuberculosis-positive specimens in the non-M. tuberculosis culture supernatants or control specimens. This yielded a sensitivity of 95.4% and a specificity of 100% for the ESAT-6-specific ELISA. The CFP-10 ELISA presented less satisfactory sensitivity and specificity, of respectively 81.6% and 92.2%. Results showed positive detection rates of ESAT-6 and CFP-10 of 86.8% (33/38) and 76.3% (29/38) for the diagnosis of tuberculous pleural effusion in patients bacteriologically negative for M. tuberculosis culture.CONCLUSION: The ESAT-6 and CFP-10 ELISAs incorporating mAbs generated in this study serve as potential tools in the laboratory diagnosis of TB.
ISSN:1027-3719
1815-7920
DOI:10.5588/ijtld.10.0393