Assessing Proficiency of Interpretation of Rapid Human Immunodeficiency Virus Assays in Nonlaboratory Settings: Ensuring Quality of Testing

Rapid antibody tests for the detection of human immunodeficiency virus (HIV) offer an effective means of providing a timely result of HIV serostatus to individuals. The increased use of rapid HIV antibody tests outside the laboratory has highlighted the need for new, cost-effective quality assurance...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Clinical Microbiology 2008-05, Vol.46 (5), p.1692-1697
Hauptverfasser: Learmonth, Kate M, McPhee, Dale A, Jardine, Darren K, Walker, Sandy K, Aye, Thein-Thein, Dax, Elizabeth M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Rapid antibody tests for the detection of human immunodeficiency virus (HIV) offer an effective means of providing a timely result of HIV serostatus to individuals. The increased use of rapid HIV antibody tests outside the laboratory has highlighted the need for new, cost-effective quality assurance methods to be developed for use in nonlaboratory-based and resource-limited settings. Photographed rapid HIV test results were used in a modified external quality assessment scheme to assess the interpretation proficiency and, therefore, to assess the feasibility of using this method as a basis for a quality assessment program for nonlaboratory-based testing. Participants (n = 148), both experienced and inexperienced in the performance and interpretation of rapid HIV testing, interpreted the photographed results of five rapid HIV assays. These were scored according to the degree of technical discordance. Error scores were grouped according to each participant's technical experience. The accuracy of interpretation for four of the five assays was between 80 and 97%, indicating that the photographed results of samples, including those difficult to read or borderline difficult to read, can be used to assess the proficiency of test operators in interpreting results. Participants had greater difficulty in interpreting samples of weak reactivity; this was consistent across the five assays. Experience played an important role in accurate interpretation, with experienced laboratory participants exhibiting greater proficiency (P < 0.05) in interpreting the results of three of the five rapid HIV assays. It was established that photographed results of rapid HIV assays could be interpreted with accuracy and demonstrated that prior experience resulted in a more accurate interpretation performance.
ISSN:0095-1137
1098-660X
1098-660X
1098-5530
DOI:10.1128/JCM.01761-07