Detection of Vibration Transmitted Through an Object Grasped in the Hand
1 Krieger Mind/Brain Institute; 2 Department of Neuroscience; and 3 Biomedical Engineering Department, The Johns Hopkins University, Baltimore, Maryland 21218 Brisben, A. J., S. S. Hsiao, and K. O. Johnson. Detection of vibration transmitted through an object grasped in the hand. A tool or pro...
Gespeichert in:
Veröffentlicht in: | Journal of neurophysiology 1999-04, Vol.81 (4), p.1548-1558 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 1 Krieger Mind/Brain Institute;
2 Department of Neuroscience; and
3 Biomedical Engineering Department, The Johns
Hopkins University, Baltimore, Maryland 21218
Brisben, A. J.,
S. S. Hsiao, and
K. O. Johnson.
Detection of vibration transmitted through an object grasped in the
hand. A tool or probe often functions as an extension of the hand, transmitting vibrations to the hand to produce a percept
of the object contacting the tool or probe. This paper reports the
psychophysical results of a combined psychophysical and
neurophysiological study of the perception of vibration transmitted through a cylinder grasped in the hand. In the first part of the psychophysical study, 19 subjects grasped a cylinder, 32 mm diam, with
an embedded motor that caused vibration parallel to the axis of the
cylinder. The relationship between threshold and frequency was the
traditional U-shaped function with a minimum between 150 and 200 Hz.
Except a study by Békésy in which subjects grasped a rod that vibrated parallel to the skin surface, thresholds above 20 Hz were lower and the slopes were steeper than any reported previously.
Thresholds were 20 Hz was based on activity in
Pacinian afferents. The extreme sensitivity compared with previous
reports may have resulted from differences in contact area, direction
of vibration, contact force, and the shape of the stimulus probe. The
effects of each of these variables were studied. At 40 and 300 Hz
(frequencies near the lower and upper end of the Pacinian range)
thresholds were 9.8 and 18.5 dB (68 and 88%) lower, respectively, when
subjects grasped the cylinder than when a 1-mm-diam probe vibrated
perpendicular to the skin. These differences were accounted for as
follows: 1 ) thresholds at a single fingerpad obtained with
the large cylindrical surface were, on average, 20 and 60% lower,
respectively, than thresholds with the punctate probe; 2 )
thresholds at the palm were, on average, 15 and 40% lower,
respectively, than at the fingerpads; 3 ) thresholds obtained
when the subjects grasped the cylinder averaged 40 and 20% less,
respectively, than when the cylinder contacted only the palm;
4 ) thresholds with the cylinder contacting two fingers were
10 and 30% lower, respectively, than thresholds with the cylinder
contacting a single finger; and 5 ) thresholds with vibration parallel |
---|---|
ISSN: | 0022-3077 1522-1598 |
DOI: | 10.1152/jn.1999.81.4.1548 |