Revisiting large break LOCA with the CATHARE-3 three-field model

► CATHARE 3 enables a three-field analysis of a LB LOCA. ► Reflooding experiments in isolated rod bundles are satisfactory predicted. ► A BETHSY integral test simulation supports the CATHARE 3 3-field assessment. Some aspects of large break LOCA analysis (steam binding, oscillatory reflooding, top-d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear engineering and design 2011-11, Vol.241 (11), p.4487-4496
Hauptverfasser: Valette, Michel, Pouvreau, Jérôme, Bestion, Dominique, Emonot, Philippe
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:► CATHARE 3 enables a three-field analysis of a LB LOCA. ► Reflooding experiments in isolated rod bundles are satisfactory predicted. ► A BETHSY integral test simulation supports the CATHARE 3 3-field assessment. Some aspects of large break LOCA analysis (steam binding, oscillatory reflooding, top-down reflooding) are expected to be improved in advanced system codes from more detailed description of flows by adding a third field for droplets. The future system code CATHARE-3 is under development by CEA and supported by EDF, AREVA-NP and IRSN in the frame of the NEPTUNE project and this paper shows some preliminary results obtained in reflooding conditions. A three-field model has been implemented, including vapor, continuous liquid and liquid droplet fields. This model features a set of nine equations of mass, momentum and energy balance. Such a model allows a more detailed description of the droplet transportation from core to steam generator, while countercurrent flow of continuous liquid is allowed. Code assessment against reflooding experiments in a rod bundle is presented, using 1D meshing of the bundle. Comparisons of CATHARE-3 simulations against data series from PERICLES and RBHT full scale experiments show satisfactory results. Quench front motions are well predicted, as well as clad temperatures in most of the tested runs. The BETHSY 6.7C Integral Effect Test simulating the gravity driven reflooding process in a scaled PWR circuit is then compared to CATHARE-3 simulation. The three-field model is applied in several parts of the circuit: core, upper plenum, hot leg and steam generator, represented by either 1D or 3D modules, while the classic six-equation model is used in the other parts of the loop. An analysis of these first results is presented and future work is defined for improving the droplet behavior simulation in both the upper plenum and the hot legs.
ISSN:0029-5493
1872-759X
DOI:10.1016/j.nucengdes.2011.04.019