Radon measurements by nuclear track detectors in dwellings in Oke-Ogun area, South-Western, Nigeria
An indoor radon survey of a total of 77 dwellings randomly selected in 10 districts in Oke-Ogun area of Oyo state, South-western Nigeria was carried out using CR-39 detectors. The CR-39 detectors were placed in the bedrooms and living rooms and exposed for 6 months and then etched in NaOH 6.25 N sol...
Gespeichert in:
Veröffentlicht in: | Radiation protection dosimetry 2012-03, Vol.148 (4), p.475-481 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An indoor radon survey of a total of 77 dwellings randomly selected in 10 districts in Oke-Ogun area of Oyo state, South-western Nigeria was carried out using CR-39 detectors. The CR-39 detectors were placed in the bedrooms and living rooms and exposed for 6 months and then etched in NaOH 6.25 N solution at 90 °C for 3 h. Mean concentrations amount to 255 ± 47 and 259 ± 67 Bq m(-3) in the living rooms and bedrooms, respectively. The lowest radon concentration (77 ± 29 Bq m(-3)) was found in Igbeti, whereas the highest was found in Okeho (627 ± 125 Bq m(-3)). The annual exposure of dwellers was estimated to fall |
---|---|
ISSN: | 0144-8420 1742-3406 |
DOI: | 10.1093/rpd/ncr196 |