Mediastinoscopy in Patients With Lung Cancer and Negative Endobronchial Ultrasound Guided Needle Aspiration

Background Endobronchial ultrasound with transbronchial needle aspiration (EBUS-TBNA) has been proposed as a safe, less-invasive alternative to mediastinoscopy to stage mediastinal lymph nodes in patients with lung cancer. We evaluated the negative predictive value of EBUS-TBNA in lung cancer patien...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 2010-12, Vol.90 (6), p.1753-1757
Hauptverfasser: Defranchi, Sebastian A., MD, Edell, Eric S., MD, Daniels, Craig E., MD, Prakash, Udaya B.S., MD, Swanson, Karen L., DO, Utz, James P., MD, Allen, Mark S., MD, Cassivi, Stephen D., MD, Deschamps, Claude, MD, Nichols, Francis C., MD, Shen, K. Robert, MD, Wigle, Dennis A., MD, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Endobronchial ultrasound with transbronchial needle aspiration (EBUS-TBNA) has been proposed as a safe, less-invasive alternative to mediastinoscopy to stage mediastinal lymph nodes in patients with lung cancer. We evaluated the negative predictive value of EBUS-TBNA in lung cancer patients suspected of having N2 nodal metastases. Methods This study is a single-institution retrospective review of cases with suspected or confirmed lung cancer undergoing mediastinoscopy after a negative EBUS-TBNA between June 2006 and February 2008. Results A total of 494 patients underwent EBUS-TBNA during the study period. Twenty-nine patients with suspected or confirmed lung cancer had a negative EBUS-TBNA and underwent subsequent mediastinoscopy. Mediastinoscopy was performed for findings suspicious of N2 disease based on noninvasive imaging. Mediastinoscopy found metastatic nodes in eight of 29 patients (28%) for a patient-specific negative predictive value of EBUS-TBNA of 72% (95% CI, 56% to 89%). Mediastinal lymph node dissection found four further patients with positive N2 nodes (19%). The EBUS-TBNA and mediastinoscopy sampled the same lymph node station on 36 occasions in the 29 patients. The average lymph node size was 10 mm. Mediastinoscopy was positive in 5 of 36 stations, for a nodal-specific negative predictive value of EBUS-TBNA of 86% (95% CI, 75% to 97%). Conclusions Endobronchial ultrasound with transbronchial needle aspiration can effectively sample mediastinal lymph node stations in patients with lung cancer. However, in this early experience, 28% of patients with high clinical suspicion of nodal disease had N2 mediastinal nodal metastases confirmed by mediastinoscopy despite negative EBUS-TBNA.
ISSN:0003-4975
1552-6259
DOI:10.1016/j.athoracsur.2010.06.052