Liquid chromatography–mass spectrometry method for the quantification of tamoxifen and its metabolite 4-hydroxytamoxifen in rat plasma: Application to interaction study with biochanin A (an isoflavone)
Tamoxifen is the agent of choice for the treatment of estrogen receptor-positive breast cancer. Tamoxifen is a substrate of P-glycoprotein (P-gp) and microsomal cytochrome P450 (CYP) 3A, and biochanin A (BCA) is an inhibitor of P-gp and CYP3A. Hence, it could be expected that BCA would affect the ph...
Gespeichert in:
Veröffentlicht in: | Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2011-10, Vol.879 (27), p.2845-2851 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Tamoxifen is the agent of choice for the treatment of estrogen receptor-positive breast cancer. Tamoxifen is a substrate of P-glycoprotein (P-gp) and microsomal cytochrome P450 (CYP) 3A, and biochanin A (BCA) is an inhibitor of P-gp and CYP3A. Hence, it could be expected that BCA would affect the pharmacokinetics of tamoxifen. In the present study we have developed and validated a simple, sensitive and specific LC–ESI-MS/MS method for the simultaneous quantification of tamoxifen and its metabolite 4-hydroxytamoxifen with 100
μL rat plasma using centchroman as an internal standard (IS). Tamoxifen, 4-hydroxytamoxifen and IS were separated on a Supelco Discovery C18 (4.6
mm
×
50
mm, 5.0
μm) column under isocratic condition using 0.01
M ammonium acetate (pH 4.5):acetonitrile (10:90, v/v) as a mobile phase. The mobile phase was delivered at a flow rate of 0.8
mL/min. The method was proved to be accurate and precise at linearity range of 0.78–200
ng/mL with a correlation coefficient (
r) of ≥0.996. The intra- and inter-day assay precision ranged from 1.89 to 8.54% and 3.97 to 10.26%, respectively; and intra- and inter-day assay accuracy was between 87.63 and 109.06% and 96 and 103.89%, respectively for both the analytes. The method was successfully applied to study the effect of oral co-administration of BCA (an isoflavone) on the pharmacokinetics of tamoxifen and 4-hydroxytamoxifen in female rats. The coadministration of BCA caused no significant changes in the pharmacokinetics of tamoxifen and 4-hydroxytamoxifen. However, the peak plasma concentration (
C
max) of 4-hydroxytamoxifen in BCA pretreated rats was significantly (
P
<
0.05) lower than those from control group. |
---|---|
ISSN: | 1570-0232 1873-376X |
DOI: | 10.1016/j.jchromb.2011.07.036 |