Angioplasty and Stenting for Intracranial Atherosclerotic Stenosis With Nitinol Stent: Factors Affecting Technical Success and Patient Safety

Angioplasty and stenting using nitinol stents is a recognized treatment option for intracranial atherosclerosis. To identify procedure-related factors that may affect patient safety and technical outcome. In this prospective study of 57 consecutive patients, the primary end points were intraprocedur...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Neurosurgery 2012-03, Vol.70 (3), p.104-113
Hauptverfasser: HO YU, Simon Chun, HONG LEUNG, Thomas Wai, YEE HUNG, Esther Hiu, TUNG LEE, Kwok, SING WONG, Lawrence Ka
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Angioplasty and stenting using nitinol stents is a recognized treatment option for intracranial atherosclerosis. To identify procedure-related factors that may affect patient safety and technical outcome. In this prospective study of 57 consecutive patients, the primary end points were intraprocedural technical problems, periprocedure morbidity, and complications. Major periprocedure complication was defined as all stroke or death at 30 days. Technical failure was defined as the inability to complete the procedure because of technical or safety problems. Procedure failure was defined as a procedure outcome of technical failure or major periprocedure complication. Secondary end points were procedure-related factors that may affect patient safety and technical outcome. Procedure failure rate was 12.3% (7/57) (major periprocedure complication rate, 5.3% [3/57]; technical failure rate, 7% [4/57]). Initial failure in tracking of balloon or stent occurred in 20 patients, other technical problems occurred in 11 patients, including kinking or trapping of balloon catheter (2 cases), difficulty in unsheathing of stent (3 cases), forward migration of stent during deployment (4 cases), trapping of nose cone after stent deployment (1 case), fracture of delivery system (2 cases), and guidewire fracture (1 case). Unfavorable vascular morphology signified by the presence of 2 or more reverse curves along the access path was found to associate with initial failure in the tracking of instruments (OR = ∞), and occurrence of other technical problems (OR = 25). Procedure-related factors could be identified and lead to improvements in patient safety and technical outcome. Tortuous vascular morphology is a key factor to be overcome.
ISSN:0148-396X
2332-4252
1524-4040
DOI:10.1227/NEU.0b013e3182320bb0