Numerical prediction of jet behavior of thermal vapor compressor

In the present study, Fluent 6.3, CFD code was applied to study the jet behavior inside the thermal vapor compressor. The effects of back pressure on the entrainment ratios and the jet behavior were investigated. It was revealed that the effect of the back pressures was due to the air curtain effect...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Desalination and water treatment 2011-09, Vol.33 (1-3), p.248-254
Hauptverfasser: Yang, K.M., Lee, H.M., Jung, H.H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In the present study, Fluent 6.3, CFD code was applied to study the jet behavior inside the thermal vapor compressor. The effects of back pressure on the entrainment ratios and the jet behavior were investigated. It was revealed that the effect of the back pressures was due to the air curtain effect of the primary jet. The entrainment rate was linearly dependent on the distance from the nozzle exit. The displacement effect by the boundary layer thickness could be considered to be negligible. The abrupt change in the wall static pressure at the mixing tube or the throat could be used as the criteria for well operation and well design.
ISSN:1944-3986
1944-3994
1944-3986
DOI:10.5004/dwt.2011.2645