Nonenzymatic continuous glucose monitoring in human whole blood using electrified nanoporous Pt

► Nanoporous platinum was utilized as nonenzymatic glucose sensor electrode material. ► Layered polymer outer membrane was adopted for sensor application to biological sample. ► Nonenzymatic glucose response in 100% human serum and whole blood were successful. ► The sensor's autoclave compatibi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biosensors & bioelectronics 2012-01, Vol.31 (1), p.284-291
Hauptverfasser: Park, Sangyun, Park, Sejin, Jeong, Ran-A., Boo, Hankil, Park, Jeyoung, Kim, Hee Chan, Chung, Taek Dong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:► Nanoporous platinum was utilized as nonenzymatic glucose sensor electrode material. ► Layered polymer outer membrane was adopted for sensor application to biological sample. ► Nonenzymatic glucose response in 100% human serum and whole blood were successful. ► The sensor's autoclave compatibility and long term stability were characterized. This paper describes the first devised method for the nonenzymatic and electrochemical glucose monitoring in 100% human whole blood and serum. The nanoporous Pt electrode allows for the selective amplification of glucose oxidation in the presence of electroactive interfering species without the need for enzymatic reaction. The outer membrane was particularly optimized to allow glucose molecules to be electrochemically detected against the numerous constituents of human blood. The proposed sensor provided reproducible amperometric responses to glucose in human serum and whole blood. Its sensitivity was maintained for at least 7h under constantly electrified conditions, and continued to work properly after 30 days of storage in human whole blood and serum. Unlike the enzyme-based glucose sensors, it was found to be minimally affected by thermal fluctuation, so as to remain successful even after steam sterilization at high temperature (134°C) and pressure (0.22Mpa). The unprecedented long-term stability and sterilization compatibility observed herein suggest a promising alternative to conventional enzymatic glucose sensors for many analytical and clinical applications, particularly for continuous glucose monitoring devices designed to potentially lead to a closed-loop artificial pancreas by combining them with an insulin pump.
ISSN:0956-5663
1873-4235
DOI:10.1016/j.bios.2011.10.033