Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography

Aim To compare the feasibility, accuracy, and effective radiation dose (ED) of multidetector computed tomography (MDCT) in the detection of coronary artery disease using a combined ED-saving strategy including prospective electrocardiogram (ECG) triggering with a short x-ray window and a body mass i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical radiology 2012-03, Vol.67 (3), p.207-215
Hauptverfasser: Pontone, G, Andreini, D, Bartorelli, A.L, Bertella, E, Mushtaq, S, Foti, C, Formenti, A, Chiappa, L, Annoni, A, Cortinovis, S, Baggiano, A, Conte, E, Bovis, F, Veglia, F, Ballerini, G, Agostoni, P, Fiorentini, C, Pepi, M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Aim To compare the feasibility, accuracy, and effective radiation dose (ED) of multidetector computed tomography (MDCT) in the detection of coronary artery disease using a combined ED-saving strategy including prospective electrocardiogram (ECG) triggering with a short x-ray window and a body mass index (BMI)-adapted imaging protocol using adaptive statistical iterative reconstruction (ASIR; group 1), in comparison with a prospective ECG triggering strategy alone (group 2). Materials and methods One hundred and seventy patients scheduled for invasive coronary angiography (ICA) were evaluated. Fourteen patients were not eligible for MDCT. The remaining 156 patients were randomized to group 1 (78 patients) and group 2 (78 patients). Eight and 11 patients in groups 1 and 2, respectively, were excluded after randomization because the patients’ heart rates were >65 beats/min. MDCT images were assessed for feasibility, signal-to-noise ration (SNR), and contrast-to-noise ratio (CNR), accuracy in detection of coronary stenoses >50% versus ICA and for ED. Results The feasibility, SNR, CNR, accuracy in a segment-based and patient-based model were similar in both groups (97 versus 95%, 14.5 ± 3.9 versus 14.2 ± 4.1, 16 ± 4.6 versus 16.5 ± 4.4, 95 versus 94% and 97 versus 99%, respectively). The ED in group 1 was 72% lower than in group 2 (2.1 ± 1.2 versus 7.5 ± 1.8 mSv, respectively; p < 0.01). Conclusions The use of a multi-parametric ED saving protocol results in a significant reduction in ED without a negative impact on accuracy.
ISSN:0009-9260
1365-229X
DOI:10.1016/j.crad.2011.07.042