Temperature-insensitive strain measurement using a birefringent interferometer based on a polarization-maintaining photonic crystal fiber
We propose a novel and simple scheme for a temperature-insensitive strain measurement by using a birefringent interferometer configured by a polarization-maintaining photonic crystal fiber (PM-PCF). The wavelength-dependent periodic transmission in a birefringent interferometer can be achieved by us...
Gespeichert in:
Veröffentlicht in: | Applied physics. B, Lasers and optics Lasers and optics, 2009-05, Vol.95 (2), p.383-387 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We propose a novel and simple scheme for a temperature-insensitive strain measurement by using a birefringent interferometer configured by a polarization-maintaining photonic crystal fiber (PM-PCF). The wavelength-dependent periodic transmission in a birefringent interferometer can be achieved by using a PM-PCF between two linear polarizers. Since the PM-PCF is composed of a single material, such as silica, the peak wavelength shift with temperature variation can be negligible because of the small amount of the birefringence change of the PM-PCF with temperature change. The measured temperature sensitivity is −0.3 pm/°C. However, the peak wavelength can be changed by strain because the peak wavelength shift is directly proportion to strain change. The strain sensitivity is measured to be 1.3 pm/με in a strain range from 0 to 1600 με. The measurement resolution of the strain is estimated to be 2.1 με. The proposed scheme has advantages of simple structure and low loss without a Sagnac loop, temperature insensitivity, ease installation, and short length of a sensing probe compared with a conventional PMF-based Sagnac loop interferometer. |
---|---|
ISSN: | 0946-2171 1432-0649 |
DOI: | 10.1007/s00340-008-3350-6 |