Corrosion behaviour of copper under chloride-containing thin electrolyte layer
► Corrosion behaviour of copper under thin electrolyte layers (TEL) with various thicknesses was investigated. ► Corrosion rate increases with decreasing layer thickness during the initial stage. ► Corrosion rate follows the order 300 > 402 > 199 > bulk solution > 101 μm after long time...
Gespeichert in:
Veröffentlicht in: | Corrosion science 2011-10, Vol.53 (10), p.3289-3298 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ► Corrosion behaviour of copper under thin electrolyte layers (TEL) with various thicknesses was investigated. ► Corrosion rate increases with decreasing layer thickness during the initial stage. ► Corrosion rate follows the order 300
>
402
>
199
>
bulk solution
>
101
μm after long time immersion. ► A corrosion model of copper under chloride-containing TEL is proposed.
The corrosion behaviour of copper under chloride-containing thin electrolyte layers (TEL) was investigated using electrochemical impedance spectroscopy (EIS), cathodic polarization, linear polarization, SEM/EDS and XRD. The results indicate that the copper corrosion rate increases as TEL thickness decreases during the initial stages. After 192
h of immersion, the corrosion rate of copper under TEL in this order: 300
>
402
>
199
>
bulk solution
>
101
μm. The corrosion behaviour is uniform under TEL, and pitting is the primary corrosion type in the bulk solution. A corrosion model of the behaviour of copper under chloride-containing TEL is proposed. |
---|---|
ISSN: | 0010-938X 1879-0496 |
DOI: | 10.1016/j.corsci.2011.06.004 |