Comparison of the Results of Hernia Defect Plasty with Standard and Light Surgical Meshes with Identical Knitted Structure

Standard and light surgical meshes with identical knitted structure: Parietene Standard/Parietene Light and Premilene/Optilene were chosen for hernioplasty in 20 rats. Six months after surgery, the complications were primarily related to inflammation in groups with implanted standard meshes and with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Bulletin of experimental biology and medicine 2011-02, Vol.150 (4), p.459-464
Hauptverfasser: Anurov, M. V., Titkova, S. M., Oettinger, A. P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Standard and light surgical meshes with identical knitted structure: Parietene Standard/Parietene Light and Premilene/Optilene were chosen for hernioplasty in 20 rats. Six months after surgery, the complications were primarily related to inflammation in groups with implanted standard meshes and with prosthesis deformation in groups with light meshes. The character of complications was determined by characteristics of knitting structure and mechanical proprieties of surgical meshes.
ISSN:0007-4888
1573-8221
DOI:10.1007/s10517-011-1168-4