Pretreatment of acrylic fiber manufacturing wastewater by the Fenton process

Fenton process was employed to pretreat the acrylic fiber manufacturing wastewater. The operation conditions were as follows: H 2O 2 and ferrous dosages were 100–800 mg/L; pH value was 1–7; reaction time was 0.5–4.0 h. In terms of COD removal and biodegradability improvement, the optimal conditions...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Desalination 2012-01, Vol.284 (4), p.62-65
Hauptverfasser: Li, Jin, Luan, Zhaokun, Yu, Lian, Ji, Zhongguang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Fenton process was employed to pretreat the acrylic fiber manufacturing wastewater. The operation conditions were as follows: H 2O 2 and ferrous dosages were 100–800 mg/L; pH value was 1–7; reaction time was 0.5–4.0 h. In terms of COD removal and biodegradability improvement, the optimal conditions were as follows: ferrous content was 300 mg/L; hydrogen peroxide was 500 mg/L; pH value was 3.0; reaction time was 2 h. With these conditions, the overall COD removal and effluent B/C could arrive at 65.5% and 0.529 respectively. The biodegradability of the acrylic fiber manufacturing wastewater was increased by 429%. It was unnecessary to achieve complete mineralization of the organic compounds into carbon dioxide and water. Partial oxidation of intermediate compounds could minimize the consumption of chemical reagents and result in substantial reduction of COD and toxicity. The further biological treatment was favored by acquiring degradable low molecular weight components. ► Fenton process was used to pretreat the acrylic fiber manufacturing wastewater. ► The running parameters and mechanism of each unit were studied. ► The enhancing biodegradability made the post biological treatment possible.
ISSN:0011-9164
1873-4464
DOI:10.1016/j.desal.2011.08.037