Response of lead metaniobate acoustic emission sensors to gamma irradiation

Piezoelectric (PE) acoustic emission (AE) sensors were exposed to hundreds of kGy from Co-60 gamma rays. Recalibration of gamma-irradiated sensors showed a sensitivity decline of 8.4% per 100 kGy. Exposure of lead metaniobate disc specimens, the sensor ferroelectric material, to /spl sim/1 MGy revea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 2005-12, Vol.52 (6), p.2583-2590
Hauptverfasser: Holbert, K.E., Sankaranarayanan, S., McCready, S.S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Piezoelectric (PE) acoustic emission (AE) sensors were exposed to hundreds of kGy from Co-60 gamma rays. Recalibration of gamma-irradiated sensors showed a sensitivity decline of 8.4% per 100 kGy. Exposure of lead metaniobate disc specimens, the sensor ferroelectric material, to /spl sim/1 MGy revealed a capacitance increase and PE voltage (g/sub 33/) coefficient decrease with gamma dose. The planar coupling factor (k/sub p/) and mechanical quality factor (Q/sub m/) exhibited small reductions. The AE sensors were also subjected to nuclear radiation from a pulse reactor.
ISSN:0018-9499
1558-1578
DOI:10.1109/TNS.2005.860708