Response of lead metaniobate acoustic emission sensors to gamma irradiation
Piezoelectric (PE) acoustic emission (AE) sensors were exposed to hundreds of kGy from Co-60 gamma rays. Recalibration of gamma-irradiated sensors showed a sensitivity decline of 8.4% per 100 kGy. Exposure of lead metaniobate disc specimens, the sensor ferroelectric material, to /spl sim/1 MGy revea...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on nuclear science 2005-12, Vol.52 (6), p.2583-2590 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Piezoelectric (PE) acoustic emission (AE) sensors were exposed to hundreds of kGy from Co-60 gamma rays. Recalibration of gamma-irradiated sensors showed a sensitivity decline of 8.4% per 100 kGy. Exposure of lead metaniobate disc specimens, the sensor ferroelectric material, to /spl sim/1 MGy revealed a capacitance increase and PE voltage (g/sub 33/) coefficient decrease with gamma dose. The planar coupling factor (k/sub p/) and mechanical quality factor (Q/sub m/) exhibited small reductions. The AE sensors were also subjected to nuclear radiation from a pulse reactor. |
---|---|
ISSN: | 0018-9499 1558-1578 |
DOI: | 10.1109/TNS.2005.860708 |