Experimental study on sudden-short-circuit characteristic of synchronous generator with SCFCL
Superconducting fault current limiters (SCFCLs) are expected to improve the reliability of power systems. An SCFCL of a transformer type with adjustable trigger current level was proposed. Three SCFCLs of this type for 3-phase AC power source were designed and made. The trigger current level of each...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 2001-03, Vol.11 (1), p.2343-2346 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Superconducting fault current limiters (SCFCLs) are expected to improve the reliability of power systems. An SCFCL of a transformer type with adjustable trigger current level was proposed. Three SCFCLs of this type for 3-phase AC power source were designed and made. The trigger current level of each trial SCFCL can be adjusted to equal value, and the SCFCLs can be used as a 3-phase SCFCL. As preliminary tests, sudden-short circuit tests with a 20 kVA synchronous generator are carried out. Limiting tests of the 3-phase SCFCL at fault are carried out with the synchronous generator. The effect of 3-phase SCFCL and the characteristics of the synchronous generator are studied experimentally. |
---|---|
ISSN: | 1051-8223 1558-2515 |
DOI: | 10.1109/77.920331 |