Noise analysis in air-coupled PVDF ultrasonic sensors
In this paper we analyze the noise generated in a piezo-polymer based sensor for low frequency ultrasound in air. The sensor includes two curved PVDF transducers for medium and short range applications. A lumped RLC equivalent circuit was derived from the measurement of the transducer's electri...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on ultrasonics, ferroelectrics, and frequency control ferroelectrics, and frequency control, 2000-11, Vol.47 (6), p.1432-1437 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper we analyze the noise generated in a piezo-polymer based sensor for low frequency ultrasound in air. The sensor includes two curved PVDF transducers for medium and short range applications. A lumped RLC equivalent circuit was derived from the measurement of the transducer's electrical admittance, in air, by taking into account both mechanical and dielectric losses, which we suppose are the major sources of noise in similar devices. The electrical model was used to study and optimize the noise performance of a 61 kHz transducer and to simulate the electrical behavior of the complete transmitter-receiver system. The validity of the overall electrical model with low noise was confirmed after verifying, with Pspice, agreement of the practical and theoretical results. |
---|---|
ISSN: | 0885-3010 1525-8955 |
DOI: | 10.1109/58.883532 |