Measurement of mechanical properties on gap healing in a rabbit osteotomy model until the remodeling stage

Abstract Background The most important issue in the assessment of fracture healing is to acquire information about the restoration of the mechanical integrity of bone. Many researchers have attempted to monitor stiffness either directly or indirectly for the purpose of assessing strength, as strengt...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical biomechanics (Bristol) 2012-01, Vol.27 (1), p.99-104
Hauptverfasser: Tobita, Kenji, Ohnishi, Isao, Matsumoto, Takuya, Ohashi, Satoru, Bessho, Masahiko, Kaneko, Masako, Nakamura, Kozo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background The most important issue in the assessment of fracture healing is to acquire information about the restoration of the mechanical integrity of bone. Many researchers have attempted to monitor stiffness either directly or indirectly for the purpose of assessing strength, as strength has been impossible to assess directly in clinical practice. The purpose of this study was thus to determine the relationship between bending stiffness and strength using mechanical testing at different times during the healing process. Methods Unilateral, transverse, mid-tibial osteotomies with a 2-mm gap were performed in 28 rabbits. The osteotomy site was stabilized using a double-bar external fixator. The animals were divided into four groups (n = 7/group/time point; 4, 6, 8 and 12 weeks). A series of images from micro-computed tomography of the gap was evaluated to detect the stage of fracture healing and a 4-point bending test was performed to measure stiffness and strength. Relative stiffness and strength values were also acquired from calculation of ratios relative to those of the non-osteotomized contralateral bones. Findings Formation of cortex and medullary canal at the gap was seen in the 12-week group and would represent the remodeling stage. In addition, the relationship between stiffness and strength remained almost linear until at least 12 weeks. However, stiffness recovered much more rapidly than strength. Interpretation Strength was not fully restored until the later stages of fracture healing. However, the current study demonstrated that stiffness could be monitored as a surrogate marker of strength until at least the remodeling stage.
ISSN:0268-0033
1879-1271
DOI:10.1016/j.clinbiomech.2011.07.005