Improved Evaluation of Equivalent Top-Down Load-Displacement Curve from a Bottom-Up Pile Load Test
A modified procedure is presented in this study to evaluate the equivalent top-down load-displacement curve in a bottom-up pile load test considering elastic shortening. On the basis of the results of a parametric study on a bored pile in normally consolidated cohesive soils under undrained conditio...
Gespeichert in:
Veröffentlicht in: | Journal of geotechnical and geoenvironmental engineering 2011-06, Vol.137 (6), p.568-578 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A modified procedure is presented in this study to evaluate the equivalent top-down load-displacement curve in a bottom-up pile load test considering elastic shortening. On the basis of the results of a parametric study on a bored pile in normally consolidated cohesive soils under undrained conditions, varying shear strength distribution and pile slenderness ratio, it was concluded that the pile shortening caused by the skin-friction component of the load in a top-down test can be related to the measured elastic shortening in a bottom-up test. A λ-factor is used to define this relationship, that is, the ratio of the top-down to bottom-up pile shortening. The factor λ=1.0 is used for the case of a pile in soil with uniform shear strength profile, λ=2.0 for linear profiles, 1.0 |
---|---|
ISSN: | 1090-0241 1943-5606 1943-5606 |
DOI: | 10.1061/(ASCE)GT.1943-5606.0000454 |