Present Estimates of the Differences Between Thermodynamic Temperatures and the ITS-90
At the request of the Consultative Committee for Thermometry (CCT), Working Group 4 (WG4) has critically reviewed all available measurements of the differences between thermodynamic and ITS-90 temperatures, ( T − T 90 ), and documented the conversion of older data to the ITS-90. Particular attention...
Gespeichert in:
Veröffentlicht in: | International journal of thermophysics 2011, Vol.32 (1-2), p.12-25 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | At the request of the Consultative Committee for Thermometry (CCT), Working Group 4 (WG4) has critically reviewed all available measurements of the differences between thermodynamic and ITS-90 temperatures, (
T
−
T
90
), and documented the conversion of older data to the ITS-90. Particular attention has been given to the uncertainties. Based on this review, we provide consensus estimates of
T
−
T
90
for selected measurements from 0.65 K to 1358 K. We provide two analytic functions for
T
−
T
90
, one for use from 8 K to the triple point of water (
T
TPW
) and one for use above
T
TPW
. The small discontinuity of the derivative d
T
90
/
d
T
at
T
TPW
is discussed. We also identify temperature ranges where researchers are encouraged to undertake high-accuracy measurements of
T
−
T
90
. |
---|---|
ISSN: | 0195-928X 1572-9567 |
DOI: | 10.1007/s10765-011-0922-1 |