Specificity and sensitivity of the Abeta oligomer ELISA

▶ The Aβ oligomer ELISA uses the same monoclonal antibody for capture and reporting. ▶ The ELISA preferentially detects Aβ soluble oligomers but is not oligomer-specific. ▶ It also detects low molecular weight Aβ, with lower OD values than for oligomers. ▶ Because of specificity concerns, this ELISA...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of neuroscience methods 2011-02, Vol.195 (2), p.249-254
Hauptverfasser: Klaver, Andrea C., Patrias, Lynnae M., Finke, John M., Loeffler, David A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:▶ The Aβ oligomer ELISA uses the same monoclonal antibody for capture and reporting. ▶ The ELISA preferentially detects Aβ soluble oligomers but is not oligomer-specific. ▶ It also detects low molecular weight Aβ, with lower OD values than for oligomers. ▶ Because of specificity concerns, this ELISA it should be used with other methods. Abeta soluble oligomers are believed to play a key role in the development of Alzheimer's disease (AD). An enzyme-linked immunosorbent assay (ELISA) commonly used to measure these proteins uses the same monoclonal antibody as both capture and reporter antibody. The objective of this study was to examine the specificity and sensitivity of this procedure, using monoclonal anti-Abeta antibody 6E10 as capture antibody and biotinylated 6E10 as reporter antibody. At comparable concentrations of Abeta soluble oligomers and low molecular weight (LMW) Abeta peptides, optical density (OD) values were four- to five-fold higher for the oligomer preparation than for the LMW Abeta. The LMW Abeta preparation, when evaluated by western blots of gels run under native conditions, showed only one band even after storage at 4°C for more than two months, suggesting that the ELISA was detecting Abeta monomer as well as Abeta oligomers. Possible explanations for these results are that (1) the LMW Abeta preparation may contain Abeta oligomer species below the limit of detection of western blot, but still detectable by ELISA, or (2) some nonspecific binding of the LMW Abeta to the ELISA plate may have occurred, allowing its relevant epitope to remain available for binding by the reporter antibody. Because of the possibility that this ELISA may not be oligomer-specific, it seems prudent to suggest that it should be used in combination with other methods, rather than as the sole technique, for measuring Abeta oligomers in biological specimens.
ISSN:0165-0270
1872-678X
DOI:10.1016/j.jneumeth.2010.12.001