Optimal stator slot design of inverter-fed induction motor in consideration of harmonic losses
This paper proposes optimal design method of stator slot for three-phase cage induction motor fed by six-step inverter output voltage by using proposed analysis method. The finite-element method (FEM) on one phase band stator periodic condition is coupled with harmonic equivalent circuit. Using the...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on magnetics 2005-05, Vol.41 (5), p.2012-2015 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper proposes optimal design method of stator slot for three-phase cage induction motor fed by six-step inverter output voltage by using proposed analysis method. The finite-element method (FEM) on one phase band stator periodic condition is coupled with harmonic equivalent circuit. Using the FEM, the stator slot is optimally designed and the result is presented. Stator core loss and copper loss including harmonic loss are reduced by the proposed optimum slot design method. The analysis result is verified by experimental measurement. |
---|---|