The frequency of detection of unexpected diabetes mellitus during haemoglobinopathy investigations
AimsTo establish the frequency of detection of previously undiagnosed diabetes mellitus as a result of detection of an increased glycated fraction of haemoglobin during high performance liquid chromatography (HPLC) for haemoglobinopathy diagnosis.MethodsA prospective study was carried out over a 3-m...
Gespeichert in:
Veröffentlicht in: | Journal of clinical pathology 2011-10, Vol.64 (10), p.898-900 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | AimsTo establish the frequency of detection of previously undiagnosed diabetes mellitus as a result of detection of an increased glycated fraction of haemoglobin during high performance liquid chromatography (HPLC) for haemoglobinopathy diagnosis.MethodsA prospective study was carried out over a 3-month period. During that period a total of 2094 patient samples were received for haemoglobinopathy investigation and were included in the study.ResultsFifty samples were found to have an apparent increase in the glycated haemoglobin fraction and of these 38 were found to be from patients with known diabetes. Previously undiagnosed diabetes was discovered in 11 patients and it is likely that the twelfth patient also had diabetes.ConclusionsThe detection of evidence of undiagnosed diabetes during HPLC haemoglobinopathy investigations is not rare, there being four cases per month in this study. This incidental observation should be reported to clinical staff. |
---|---|
ISSN: | 0021-9746 1472-4146 |
DOI: | 10.1136/jclinpath-2011-200214 |