Influence of Rotor Position in FRA Response for Detection of Insulation Failures in Salient-Pole Synchronous Machines

Frequency response analysis (FRA) is a very common test for the diagnosis of power transformers. This paper presents some relevant results on the application of FRA to the diagnosis of rotating machines. First, a reference rotor position for obtaining the reference FRA response of a rotating machine...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on energy conversion 2011-06, Vol.26 (2), p.671-676
Hauptverfasser: Platero, C A, Blázquez, F, Frías, P, Ramírez, D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Frequency response analysis (FRA) is a very common test for the diagnosis of power transformers. This paper presents some relevant results on the application of FRA to the diagnosis of rotating machines. First, a reference rotor position for obtaining the reference FRA response of a rotating machine is proposed. Then, FRA with the proposed rotor position is used to identify faults in the stator of the machine. This paper studies turn-to-turn and ground faults in the stator for different fault resistance values. Several laboratory tests demonstrate the applicability and value of the use of FRA in the diagnosis of rotating machines.